Products / Eco pellet boilers / Biopel
NEW: The Biopel pellet boiler is a universal boiler which can be used with three kinds of burners: 16 kW, 24 kW and 30kW. The boiler is made of 6mm thick metal sheet and is distinguished by its original construction and design.
The Biopel boiler uses a modern method of heating based on biomass combustion - the combustion of wood pellets. The boiler is constructed as a unit consisting of the boiler, a stainless-steel burner, a pellet screw-feeder, an electronic controller and a feeding hopper (220 kg). The pellets are transported via a sloping screw-feeder from the hopper to the burner, where they are burned together with primary air drawn in by a blower. This is a fully automated heating system, including automatic ignition.
| Type | Biopel 16 |
Biopel 24 |
Biopel 30 |
Biopel 60 |
Biopel 80 |
|
| Maximum output | kW |
16 |
24 |
30 |
60 |
80 |
| Minimum output | kW |
4 |
4 |
4 |
10% of the burner output |
|
| Guaranteed fuel | / |
wood pellets 6-10 mm |
||||
| Boiler efficiency | % |
94 |
94 |
90 |
91.6 |
93 |
| Average fuel consumption | kg/hour |
2.5 |
2.5 |
3 |
6.5 |
8 |
| Standard hopper volume | l |
220 |
||||
| Burning time per one standard hopper volume | hour |
72-110 |
63-95 |
|||
| Minimum operating chimney draught | Pa |
10 |
10-15 |
10-15 |
||
| Flue gas duct diameter | mm |
130 |
130 |
130 |
150 |
180 |
| Minimum chimney cross-section | mm |
150 |
150 |
150 |
180 |
200 |
| Junction pieces | DN |
3/4" |
1" | 5/4" | ||
| Maximum operating overpressure | MPa |
2.5 |
||||
| Maximum electric input/voltage | W/V |
50/220 |
60/220 |
160/220 |
160/220 |
|
| Average input during operation | W |
40 |
50 |
50 |
60 |
|
| Average electricity consumption per year | kWh/year |
180 |
200 |
250 |
300 |
|
| Efficiency class | / |
3 |
||||
| Emission class | / |
3 |
||||
| CO | mg/kW |
143 |
104 |
157 |
217 |
|
| OGC | mg/kW |
7 |
4 |
8 |
7 |
|
| Dust | mg/kW |
16 |
24 |
32 |
31 |
|
Boink |
Biopel |
||||||||
| Burner power output | kW |
16 |
24 |
30 |
16 |
24 |
30 |
60 |
80 |
| Boiler height | mm |
865 |
865 |
1005 |
1307 |
1272 |
1271 |
||
| Boiler width | mm |
400 |
400 |
500 |
515 |
643 |
743 |
||
| Boiler depth | mm |
724 |
724 |
740 |
750 |
896 |
997 |
||
| Weight (boiler + burner) | kg |
180 |
180 |
280 |
230 |
385 |
480 |
||
| Flue gas duct diameter | mm |
130 |
130 |
150 |
130 |
150 |
180 |
||
| Flue gas duct distance from the ground | mm |
635 |
635 |
757 |
887.5 |
998 |
|||
| Distance of input water junction piece from the ground | mm |
99 |
99 |
99 |
276 |
270 |
|||
| Distance of output water junction piece from the ground | mm |
781 |
781 |
921 |
1031 |
1121 |
|||
| Height | mm |
1300 |
| Width | mm |
815 |
| Depth | mm |
815 |
| Weight | kg |
32.5 |
| Height | mm |
1300 |
| Width | mm |
1420 |
| Depth | mm |
810 |
| Weight | kg |
38 |
| Length | mm |
1860-3000 |
| Diameter | mm |
75 |
| Slope angle | ° |
50 |
| Weight | kg |
7-12 |
Parameters affecting the operation and ignition of pellet boilers
Function of three-way and four-way valves - presentation to download
Note: Download as .zip and unpack. Then run the eseb.exe file.
It is necessary to have Adobe Flash Player installed. Free download is available here.
Operating instructions
Chip version 6 (.doc)
Chip version 4.99 (.pdf)
Calculate and compare your own home heating costs based on the type of fuel: http://www.tzb-info.sk/t.py?t=16&i=269
DYNAMIC HEATING CONTROLLER ADEX Comfort 06 (.doc )
The use of an ASTIP PS backup power source is recommended: