Products / Eco pellet boilers / Black Star

| Type | Black Star 20 |
Black Star 30 |
|||
| Maximal output | kW |
10 |
16 |
20 |
30 |
| Nominal output | kW |
8,5 |
14,8 |
14,8 |
25,6 |
| Minimal output | kW |
10 % of the burner output |
|||
| Guaranty fuel | wood pellets 6-10 mm |
||||
| Average fuel consumption | kg/hod |
1,88-0,53 |
3,22-0,79 |
3,22-0,79 |
5,63-1,6 |
| Efficiency | % |
85-91 |
88-93 |
88-93 |
90,6-92 |
| Connection socket | DN |
5/4" |
5/4" |
5/4" |
5/4" |
| Boiler water volume | l |
35 |
35 |
45 |
45 |
| Chimney operation draught | Pa |
2-3 |
2-3 |
2-3 |
15-21 |
| Maximum electrical absorbed power/voltage | W/V |
50/220 |
50/220 |
50/220 |
60/220 |
| Height of boiler | mm |
984 |
984 |
984 |
984 |
| Width of boiler | mm |
428 |
428 |
528 |
528 |
| Depth of boiler | mm |
728 |
728 |
792 |
792 |
| Weight | kg |
160 |
160 |
210 |
210 |
| Diameter of the chimney | mm |
130 |
130 |
150 |
150 |
| Flue gas duct distance from the ground | mm |
635 |
635 |
635 |
635 |
| Distance of input water junction piece from the ground | mm |
105 |
105 |
105 |
105 |
| Distance of output water junction piece from the ground | mm |
795 |
795 |
795 |
795 |
| Height | mm |
1300 |
| Width | mm |
815 |
| Depth | mm |
815 |
| Weight | kg |
32.5 |
| Height | mm |
1300 |
| Width | mm |
1420 |
| Depth | mm |
810 |
| Weight | kg |
38 |
| Length | mm |
1860-3000 |
| Diameter | mm |
75 |
| Slope angle | ° |
50 |
| Weight | kg |
7-12 |
Parameters affecting the operation and ignition of pellet boilers
Function of three-way and four-way valves - presentation to download
Note: Download as .zip and unpack. Then run the eseb.exe file.
It is necessary to have Adobe Flash Player installed. Free download is available here.
Operating instructions
Chip version 6 (.doc)
Chip version 4.99 (.pdf)
Calculate and compare your own home heating costs based on the type of fuel: http://www.tzb-info.sk/t.py?t=16&i=269
DYNAMIC HEATING CONTROLLER ADEX Comfort 06 (.doc )
The use of an ASTIP PS backup power source is recommended: